當前位置:首頁 > 產品中心 > 西門子PLC模塊 > 西門子S7-300PLC模塊 > 西門子PLC模塊CPU314C-2PN/DP
簡要描述:西門子PLC模塊CPU314C-2PN/DP,西門子S7-300CPU314C-2PN/DP,SIMATIC S7-300, CPU 314C-2PN/DP 緊湊型CPU帶有192 KB工作存儲區(qū), 24 數(shù)字量輸入/16 數(shù)字量輸出, 4模擬量輸入, 2模擬量輸出, 1 PT100, 4 快速計數(shù)器 (60 KHZ), 1. 接口 MPI/DP 12MBIT/S, 2. 接口以太網 PROFIN
詳細介紹
西門子PLC模塊CPU314C-2PN/DP,西門子S7-300CPU314C-2PN/DP,西門子CPU314C-2PN/DP,CPU314C-2PN/DP,西門子S7-300CPU314C-2PN/DP可編程控制器
訂貨號:6ES7314-6EH04-0AB0
SIMATIC S7-300, CPU 314C-2PN/DP 緊湊型CPU帶有192 KB工作存儲區(qū), 24 數(shù)字量輸入/16 數(shù)字量輸出, 4模擬量輸入, 2模擬量輸出, 1 PT100, 4 快速計數(shù)器 (60 KHZ), 1. 接口 MPI/DP 12MBIT/S, 2. 接口以太網 PROFINET, 含 2個 PORT SWITCH, 集成 24V DC 電源, FRONT C
德國* 現(xiàn)貨銷售 質保一年 歡迎詢價
SIEMENS上海翰粵自動化系統(tǒng)有限公司
:: :
上海翰粵公司在經營活動中精益求精,具備如下業(yè)務優(yōu)勢:
SIEMENS 可編程控制器
1、 SIMATIC S7 系列PLC:S7-200、S7-1200、S7-300、S7-400、ET-200
2、 邏輯控制模塊 LOGO!230RC、230RCO、230RCL、24RC、24RCL等
3、 SITOP直流電源 24V DC 1.3A、2.5A、3A、5A、10A、20A、40A可并聯(lián).
4、HMI 觸摸屏TD200 TD400C K-TP OP177 TP177,MP277 MP377,
SIEMENS 交、直流傳動裝置
1、 交流變頻器 MICROMASTER系列:MM420、MM430、MM440、G110、G120.
MIDASTER系列:MDV
2、全數(shù)字直流調速裝置 6RA23、6RA24、6RA28、6RA70、6SE70系列
SIEMENS 數(shù)控 伺服
SINUMERIK:801、802S 、802D、802D SL、810D、840D、611U、S120
系統(tǒng)及伺報電機,力矩電機,直線電機,伺服驅動等備件銷售。
CPU 運行需要 SIMATIC 微存儲卡(MMC)。
,西門子S7-300CPU314C-2PN/DP 應用領域
CPU 314C-2 DP 是緊湊型 CPU,適合安裝在分布式結構中。通過其擴展工作存儲器,該緊湊型CPU也適用于中等規(guī)模的應用。集成的數(shù)字量和模擬量輸入和輸出可與過程信號直接連接。集成的 的PROFIBUS DP 主站/從站以及 PROFINET IO 控制器/I-設備接口,用于 PROFIBUS 和 PROFINET 的分布式連接。這使得 CPU 314C-2 PN/DP 可作為進行快速處理的分布式單元使用,也可作為 PROFIBUS 和 PROFINET 系統(tǒng)中具有低端現(xiàn)場總線系統(tǒng)的上位控制器。
集成技術工程的其他用途包括:
,西門子S7-300CPU314C-2PN/DP
CPU 314C-2 DP 安裝有:
,西門子S7-300CPU314C-2PN/DP 設計
可參數(shù)化的特性
可以使用 STEP 7 對 S7 的組態(tài)、屬性以及CPU的響應進行參數(shù)設置:
顯示功能與信息功能
集成的通訊功能
集成功能
,西門子S7-300CPU314C-2PN/DP 技術規(guī)格
| 6ES7 314-6EH04-0AB0 |
General information |
|
Hardware product version | 01 |
Firmware version | V3.3 |
Supply voltage |
|
24 V DC | Yes |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Mains buffering |
|
| 5 ms |
| 1 s |
Digital inputs |
|
|
|
| 24 V |
| Yes |
Digital outputs |
|
|
|
| 24 V |
| No |
Input current |
|
Current consumption (rated value) | 850 mA |
Current consumption (in no-load operation), typ. | 190 mA |
Inrush current, typ. | 5 A |
I²t | 0.7 A²·s |
from supply voltage L+, max. | 850 mA |
Digital inputs |
|
| 80 mA |
Digital outputs |
|
| 50 mA |
Power losses |
|
Power loss, typ. | 14 W |
Memory |
|
Type of memory | other |
Work memory |
|
| 192 kbyte |
| No |
| 64 kbyte |
Load memory |
|
| Yes |
| 8 Mbyte |
| 10 a |
Backup |
|
| Yes |
| Yes; Program and data |
CPU processing times |
|
for bit operations, typ. | 0.06 µs |
for word operations, typ. | 0.12 µs |
for fixed point arithmetic, typ. | 0.16 µs |
for floating point arithmetic, typ. | 0.59 µs |
CPU-blocks |
|
Number of blocks (total) | 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
DB |
|
| 1 024 |
| 64 kbyte |
FB |
|
| 1 024 |
| 64 kbyte |
FC |
|
| 1 024; Number range: 0 to 7999 |
| 64 kbyte |
OB |
|
| see instruction list |
| 64 kbyte |
| 1 |
| 1 |
| 2 |
| 4 |
| 1 |
| 3; OB 55, 56, 57 |
| 1; OB 61; only for PROFINET |
| 1 |
| 6 |
| 2 |
Nesting depth |
|
| 16 |
| 4 |
Counters, timers and their retentivity |
|
S7 counter |
|
| 256 |
|
|
| Yes |
| 0 |
| 255 |
| Z 0 to Z 7 |
|
|
| Yes |
| 0 |
| 999 |
IEC counter |
|
| Yes |
| SFB |
| Unlimited (limited only by RAM capacity) |
S7 times |
|
| 256 |
|
|
| Yes |
| 0 |
| 255 |
| No retentivity |
|
|
| 10 ms |
| 9 990 s |
IEC timer |
|
| Yes |
| SFB |
| Unlimited (limited only by RAM capacity) |
Data areas and their retentivity |
|
retentive data area, total | All, max. 64 KB |
Flag |
|
| 256 byte |
| Yes; MB 0 to MB 255 |
| MB 0 to MB 15 |
| 8; 1 memory byte |
Data blocks |
|
| 1 024; Number range: 1 to 16000 |
| 64 kbyte |
| Yes; via non-retain property on DB |
| Yes |
Local data |
|
| 32 kbyte; Max. 2048 bytes per block |
Address area |
|
I/O address area |
|
| 2 048 byte |
| 2 048 byte |
|
|
| 2 003 byte |
| 2 010 byte |
Process image |
|
| 2 048 byte |
| 2 048 byte |
| 2 048 byte |
| 2 048 byte |
| 256 byte |
| 256 byte |
|
|
| 136.0 to 138.7 |
| 136.0 to 137.7 |
| 800 to 809 |
| 800 to 803 |
Subprocess images |
|
| 1; With PROFINET IO, the length of the user data is limited to 1600 bytes |
Digital channels |
|
| 16 048 |
| 16 096 |
| 1 016 |
| 1 008 |
Analog channels |
|
| 1 006 |
| 1 007 |
| 253 |
| 250 |
Hardware configuration |
|
Expansion devices, max. | 3 |
Number of DP masters |
|
| 1 |
| 4 |
Number of operable FMs and CPs (recommended) |
|
| 8 |
| 8 |
| 10 |
Rack |
|
| 4 |
| 8; In rack 3 max. 7 |
Time of day |
|
Clock |
|
| Yes |
| Yes |
| 10 s; Typ.: 2 s |
| 6 wk; At 40 °C ambient temperature |
| Clock continues running after POWER OFF |
| Clock continues to run with the time at which the power failure occurred |
Operating hours counter |
|
| 1 |
| 0 |
| 0 to 2^31 hours (when using SFC 101) |
| 1 hour |
| Yes; Must be restarted at each restart |
Clock synchronization |
|
| Yes |
| Yes |
| Yes |
| Yes; With DP slave only slave clock |
| Yes |
| Yes |
| Yes |
| Yes; as client |
Digital inputs |
|
Number of digital inputs | 24 |
| 16 |
integrated channels (DI) | 24 |
Input characteristic curve in accordance with IEC 61131, type 1 | Yes |
Number of simultaneously controllable inputs |
|
|
|
| 24 |
| 12 |
|
|
| 12 |
Input voltage |
|
| 24 V |
| -3 to +5 V |
| 15 to 30 V |
Input current |
|
| 8 mA |
Input delay (for rated value of input voltage) |
|
|
|
| Yes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.) |
| 3 ms |
|
|
| 8 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency |
Cable length |
|
| 1 000 m |
| 600 m |
|
|
| 50 m; at maximum count frequency |
| not allowed |
|
|
| 1 000 m |
| 600 m |
Digital outputs |
|
Number of digital outputs | 16 |
| 4; Notice: You cannot connect the fast outputs of your CPU in parallel |
integrated channels (DO) | 16 |
Short-circuit protection | Yes; Clocked electronically |
| 1 A |
Limitation of inductive shutdown voltage to | L+ (-48 V) |
Controlling a digital input | Yes |
Switching capacity of the outputs |
|
| 5 W |
Load resistance range |
|
| 48 Ω |
| 4 kΩ |
Output voltage |
|
| L+ (-0.8 V) |
Output current |
|
| 500 mA |
| 5 mA |
| 0.6 A |
| 5 mA |
| 0.5 mA |
Parallel switching of 2 outputs |
|
| No |
| Yes |
Switching frequency |
|
| 100 Hz |
| 0.5 Hz |
| 100 Hz |
| 2.5 kHz |
Aggregate current of outputs (per group) |
|
|
|
| 3 A |
| 2 A |
|
|
| 2 A |
Cable length |
|
| 1 000 m |
| 600 m |
Analog inputs |
|
Number of analog inputs | 5 |
Integrated channels (AI) | 5; 4 x current/voltage, 1 x resistance |
Number of analog inputs for voltage/current measurement | 4 |
Number of analog inputs for resistance/resistance thermometer measurement | 1 |
permissible input frequency for current input (destruction limit), max. | 5 V |
permissible input voltage for voltage input (destruction limit), max. | 30 V; Permanent |
permissible input current for voltage input (destruction limit), max. | 0.5 mA |
permissible input current for current input (destruction limit), max. | 50 mA; Permanent |
Technical unit for temperature measurement adjustable | Yes; Degrees Celsius / degrees Fahrenheit / Kelvin |
Input ranges |
|
| Yes; ±10 V / 100 kΩ; 0 V to 10 V / 100 kΩ |
| Yes; ±20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω |
| Yes; Pt 100 / 10 MΩ |
| Yes; 0 Ω to 600 Ω / 10 MΩ |
Input ranges (rated values), voltages |
|
| Yes |
| 100 kΩ |
Input ranges (rated values), currents |
|
| Yes |
| 100 Ω |
| Yes |
| 100 Ω |
| Yes |
| 100 Ω |
Input ranges (rated values), resistance thermometers |
|
| Yes |
| 10 MΩ |
Input ranges (rated values), resistors |
|
| 3.3 V |
| 1,25 mA |
| Yes |
| 10 MΩ |
Thermocouple (TC) |
|
|
|
| No |
Characteristic linearization |
|
| Yes; by software |
| Pt 100 |
Cable length |
|
| 100 m |
Analog outputs |
|
Number of analog outputs | 2 |
Integrated channels (AO) | 2 |
Voltage output, short-circuit protection | Yes |
Voltage output, short-circuit current, max. | 55 mA |
Current output, no-load voltage, max. | 14 V |
Output ranges, voltage |
|
| Yes |
| Yes |
Output ranges, current |
|
| Yes |
| Yes |
| Yes |
Connection of actuators |
|
| Yes; Without compensation of the line resistances |
| No |
| Yes |
Load impedance (in rated range of output) |
|
| 1 kΩ |
| 0.1 µF |
| 300 Ω |
| 0.1 mH |
Destruction limits against externally applied voltages and currents |
|
| 16 V; Permanent |
| 50 mA; Permanent |
Cable length |
|
| 200 m |
Analog value creation |
|
Measurement principle | Actual value encryption (successive approximation) |
Integrations and conversion time/resolution per channel |
|
| 12 bit |
| Yes; 16.6 / 20 ms |
| 400 Hz |
| 60 / 50 Hz |
| 1 ms |
| 0.38 ms |
| 1 ms |
Settling time |
|
| 0.6 ms |
| 1 ms |
| 0.5 ms |
Encoder |
|
Connection of signal encoders |
|
| Yes |
| Yes; with external supply |
| Yes |
| Yes; Without compensation of the line resistances |
| No |
| No |
Connectable encoders |
|
| Yes |
| 1.5 mA |
Errors/accuracies |
|
Temperature error (relative to input range), (+/-) | 0.006 %/K |
Crosstalk between the inputs, min. | 60 dB |
Repeat accuracy in steady state at 25 °C (relative to input area), (+/-) | 0.06 % |
Output ripple (based on output area, bandwidth 0 to 50 kHz), (+/-) | 0.1 % |
Linearity error (relative to output range), (+/-) | 0.15 % |
Temperature error (relative to output range), (+/-) | 0.01 %/K |
Crosstalk between the outputs, min. | 60 dB |
Repeat accuracy in steady state at 25 °C (relative to output area), (+/-) | 0.06 % |
Operational limit in overall temperature range |
|
| 1 % |
| 1 % |
| 1 % |
| 1 % |
| 1 % |
Basic error limit (operational limit at 25 °C) |
|
| 0.8 %; Linearity error +/- 0.06 % |
| 0.8 %; Linearity error +/- 0.06 % |
| 0.8 %; Linearity error +/- 0.2% |
| 0.8 % |
| 0.8 % |
| 0.8 % |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency |
|
| 30 dB |
| 40 dB |
Interfaces |
|
Number of USB interfaces | 0 |
Number of parallel interfaces | 0 |
Number of 20 mA interfaces (TTY) | 0 |
Number of RS 232 interfaces | 0 |
Number of RS 422 interfaces | 0 |
Number of other interfaces | 1; Ethernet, 2-port switch, 2*RJ45 |
1st interface |
|
Interface type | Integrated RS 485 interface |
Physics | RS 485 |
Isolated | Yes |
Power supply to interface (15 to 30 V DC), max. | 200 mA |
Functionality |
|
| Yes |
| Yes |
| Yes |
| No |
MPI |
|
| 12 Mbit/s |
|
|
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| No; but via CP and loadable FB |
| Yes |
DP master |
|
| 12 Mbit/s |
| 124 |
|
|
| Yes |
| Yes |
| No |
| Yes; I blocks only |
| Yes |
| No |
| Yes |
| Yes |
| No |
| Yes |
| Yes |
| 8 |
| Yes; As subscriber |
| Yes |
|
|
| 2 kbyte |
| 2 kbyte |
|
|
| 244 byte |
| 244 byte |
DP slave |
|
| 12 Mbit/s |
| Yes; only with passive interface |
| 32 |
| 32 byte |
|
|
| Yes |
| Yes; Only with active interface |
| No |
| No |
| Yes |
| No |
| Yes; Connection configured on one side only |
| Yes |
| No |
|
|
| 244 byte |
| 244 byte |
2nd interface |
|
Interface type | PROFINET |
Physics | Ethernet RJ45 |
Isolated | Yes |
Integrated switch | Yes |
Number of ports | 2 |
Automatic detection of transmission speed | Yes; 10/100 Mbit/s |
Autonegotiation | Yes |
Autocrossing | Yes |
Change of IP address at runtime, supported | Yes |
Media redundancy |
|
| Yes |
| 200 ms; PROFINET MRP |
| 50 |
Functionality |
|
| No |
| No |
| No |
| Yes; Also simultaneously with IO-Device functionality |
| Yes; Also simultaneously with IO Controller functionality |
| Yes |
| Yes; Via TCP/IP, ISO on TCP, and UDP |
| Yes |
| 5 |
PROFINET IO Controller |
|
| 100 Mbit/s |
| 128 |
| 128 |
| 128 |
| 128 |
| 61 |
| 64 |
| 64 |
| Yes |
| Yes |
| Yes |
| 32 |
| Yes |
| 8 |
| Yes |
| 8 |
| Yes |
| 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option) |
| 250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, Technical Data" for more details) |
|
|
| Yes |
| Yes |
| Yes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32 |
| Yes; OB 61 |
| Yes; Via TCP/IP, ISO on TCP, and UDP |
|
|
| 2 kbyte |
| 2 kbyte |
| 1 024 byte |
PROFINET IO Device |
|
|
|
| Yes |
| Yes |
| Yes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32 |
| No |
| Yes; Via TCP/IP, ISO on TCP, and UDP |
| Yes |
| Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device |
| Yes |
| 2 |
|
|
| 1 440 byte; Per IO Controller with shared device |
| 1 440 byte; Per IO Controller with shared device |
|
|
| 64 |
| 1 024 byte |
PROFINET CBA |
|
| Yes |
| Yes |
Open IE communication |
|
| Yes |
| 8 |
| 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 |
| Yes |
Isochronous mode |
|
Isochronous operation (application synchronized up to terminal) | Yes; For PROFINET only |
Communication functions |
|
PG/OP communication | Yes |
Data record routing | Yes |
Global data communication |
|
| Yes |
| 8 |
| 8 |
| 8 |
| 8 |
| 22 byte |
| 22 byte |
S7 basic communication |
|
| Yes |
| 76 byte |
| 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication |
|
| Yes |
| Yes |
| Yes |
| See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) |
S5-compatible communication |
|
| Yes; via CP and loadable FC |
Open IE communication |
|
| Yes; via integrated PROFINET interface and loadable FBs |
| 8 |
| 1 460 byte |
| 32 768 byte |
| Yes |
| Yes; via integrated PROFINET interface and loadable FBs |
| 8 |
| 32 768 byte |
| Yes; via integrated PROFINET interface and loadable FBs |
| 8 |
| 1 472 byte |
Web server |
|
| Yes |
| 5 |
| Yes |
PROFINET CBA (at set setpoint communication load) |
|
| 50 % |
| 32 |
| 30 |
| 1 000 |
| 4 000 byte |
| 4 000 byte |
| 500 |
| 4 000 byte |
| 1 400 byte |
|
|
| 500 ms |
| 100 |
| 100 |
| 2 000 byte |
| 2 000 byte |
| 1 400 byte |
|
|
| 10 ms |
| 200 |
| 200 |
| 2 000 byte |
| 2 000 byte |
| 450 byte |
|
|
| 3; 2x PN OPC/1x iMap |
| 500 ms |
| 200 |
| 2 000 byte |
|
|
| Yes |
| 16 |
| 240 byte; Slave-dependent |
Number of connections |
|
| 12 |
| 11 |
| 1 |
| 1 |
| 11 |
| 11 |
| 1 |
| 1 |
| 11 |
| 8 |
| 0 |
| 0 |
| 8 |
| 10 |
| 0 |
| 0 |
| 10 |
| 32 |
| X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max. |
S7 message functions |
|
Number of login stations for message functions, max. | 12; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages | Yes |
simultaneously active Alarm-S blocks, max. | 300 |
Test commissioning functions |
|
Status block | Yes; Up to 2 simultaneously |
Single step | Yes |
Number of breakpoints | 4 |
Status/control |
|
| Yes |
| Inputs, outputs, memory bits, DB, times, counters |
| 30 |
| 30 |
| 14 |
Forcing |
|
| Yes |
| Inputs, outputs |
| 10 |
Diagnostic buffer |
|
| Yes |
| 500 |
| No |
| 100; Only the last 100 entries are retained |
| 499 |
| Yes; From 10 to 499 |
| 10 |
Service data |
|
| Yes |
Interrupts/diagnostics/status information |
|
Diagnostics indication LED |
|
| Yes |
| Yes |
Integrated Functions |
|
Number of counters | 4; See "Technological Functions" manual |
Counter frequency (counter) max. | 60 kHz |
Frequency measurement | Yes |
Number of frequency meters | 4; up to 60 kHz (see "Technological Functions" manual) |
controlled positioning | Yes |
Integrated function blocks (closed-loop control) | Yes; PID controller (see "Technological Functions" manual) |
PID controller | Yes |
Number of pulse outputs | 4; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual) |
Limit frequency (pulse) | 2.5 kHz |
Galvanic isolation |
|
Galvanic isolation digital inputs |
|
| Yes |
| No |
| Yes |
Galvanic isolation digital outputs |
|
| Yes |
| Yes |
| 8 |
| Yes |
Galvanic isolation analog inputs |
|
| Yes |
| No |
| Yes |
Galvanic isolation analog outputs |
|
| Yes |
| No |
| Yes |
Permissible potential difference |
|
between inputs and MANA (UCM) | 8 V DC |
between MANA and M internally (UISO) | 75 VDC / 60 VAC |
Ambient conditions |
|
Operating temperature |
|
| 0 °C |
| 60 °C |
Configuration |
|
Configuration software |
|
| Yes; V5.5 or higher |
programming |
|
| see instruction list |
| 8 |
| see instruction list |
| see instruction list |
|
|
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Know-how protection |
|
| Yes |
| Yes; With S7 block Privacy |
Dimensions |
|
Width | 120 mm |
Height | 125 mm |
Depth | 130 mm |
Weights |
|
Weight, approx. | 730 g
|